3) Flow chart of Digital block
The flow chart of digital block is shown below.
Normal Mode
VOUT
: Analog Output
CSCLK=”High”
> 1.0 ms
No
Digital I/O Mode
VOUT
: DATA I/O
Yes
EEPROM Write
Instruction code
: 101
EEPROM Read
Instruction code
: 110
Register Write
Instruction code
: 001
Timing chart1
VREF
Adjustment set
VTMP
Adjustment set
OSC
Adjustment set
CSCLK=”High”
(Write Time)
> 5ms
Between
CSCLK="High"
VOUT : VREF
Between
CSCLK="High"
OSC clock counting
Between
CSCLK="High"
VOUT : VTMP
Timing chart2 Timing chart3
CSCLK=”Low”
> 0.5 ms
Yes
No
Register Read
Instruction code
: 010
Pressure Threshold
Detector 1/2
Hysteresis Level
Adjustment set
Between
CSCLK="High"
VOUT : Pressure
Hysteresis Level
Pressure Threshold
Detector 1/2
Threshold
Adjustment set
Between
CSCLK="High"
VOUT
: Pressure Level
IREF
Adjustment set
Between
CSCLK="High"
VOUT : IREF
Note)
In DATA I/O mode, when the condition of CSCLK=Low > 0.5 ms
consists,
it becomes an Analog Output mode.
The state of EEPROM Write Enable and Control Register Access Enable
is required.
Flow chart of Digital block
POWER ON
Level shift
Adjustment set
Between
CSCLK="High"
VOUT : Level shift