- 40 -
7) The Initial State Setup of VOUT pin, DET1 pin and DET2 pin at Power-Up
To make the Pressure Threshold Detectors generate the correct result at power up, the initial state of VOUT pin,
and the output polarity and the detection direction of the Pressure Threshold Detectors must be set by
EEPROM (EVOUT[1:0], EINV1[0], EIN1L[0], EINV2[0], EIN2L[0]).
The relation between the data in EEPROM and the output waveform of VOUT pin, DET1 pin and DET2 pin is
explained in the following figures.
7.1) Detection Conditions: EIN1L[0]=EIN2L[0]=EINV1[0]=0h, EINV2[0]=1h, EVOUT[1:0]=0h
7.2) Detection Conditions: EIN1L[0]=EIN2L[0]=1h, EINV1[0]=0h, EINV2[0]=1h, EVOUT[1:0]=1h
DET1 pin
DET1 state
High
Low
I
nitial
state
Detection result
VDD
VOUT pin
VOUT state
Normal output
Detection threshold
VDD
VOUT pin
Detection threshold
Normal output
VSS
DET2 pin
High
Low
VOUT state
Initial
state
Detection result
DET2 state
unknown
(VDD 1V)
unknown
(VDD 1V)
VSS
unknown
(VDD 1V)
unknown
(VDD 1V)
DET1 pin
DET1 state
Low
Initial state
Detection result
VDD
VOUT pin
VOUT state
Normal output
VDD
Detection threshold
DET2 pin
DET2 state
High
Detection result
VDD
VOUT pin
VOUT state
Normal output
VDD
Detection threshold
unknown
(VDD 1V)
unknown
(VDD 1V)
unknown
(VDD 1V)
unknown
(VDD 1V)
Initial state
Przeglądanie stron 39