CONFIDENTIAL [AK8999A/AW/AD]
MS1600-E-00 2014/05
- 16 -
6) Pressure Threshold Detector 1 & 2
VDD = 3, 3.3, 5V ± 10%, Ta = -40 to 105ºC, register default, unless otherwise noted
Parameter Symbol Conditions Min. Typ. Max.
Units
Description
Pressure
detection
threshold
External input
range
Vdete
EINE1[0] = 0h
EINE2[0] = 1h
EPTH1[0] = 1h
0.1*VDD 0.9*VDD V
Pressure
detection
threshold
Internal set
value
Vdet
EPT1, 2[4:0] = 00h
0.500
*VDD
-0.05
0.500
*VDD
0.500
*VDD
+0.05
V
Pressure
detection
threshold
Internal set
value
Adjust. width
Vdet+
Max
EPT1, 2[4:0] = 10h
0.900
*VDD
V
Vdet-
Min
EPT1, 2[4:0] = 0Fh
0.125
*VDD
V
Adjust. step Vdstp 0.025
*VDD
V
Hysteresis
voltage
Adjust. width
Vhys5+
Max
VDD = 5V ± 10%
EHYS1, 2[1:0] = 1h
0.060
*VDD
-0.055
0.060
*VDD
0.060
*VDD
+0.055
V
Vhys5-
Min
VDD = 5V ± 10%
EHYS1, 2[1:0] = 2h
0.030
*VDD
-0.03
0.030
*VDD
0.030
*VDD
+0.03
V
Vhys3+
Max
VDD = 3, 3.3V ± 10%
EHYS1, 2[1:0] = 1h
0.060
*VDD
-0.035
0.060
*VDD
0.060
*VDD
+0.035
V
Vhys3-
Min
VDD = 3, 3.3V ± 10%
EHYS1, 2[1:0] = 2h
0.030
*VDD
-0.02
0.030
*VDD
0.030
*VDD
+0.02
V
Adjust. step Vhysst 0.010
*VDD
V
Pressure
detection time
Tdetr
ESCF[1:0] = 0h
180 μsec Note1)
Pressure
non-detection
time
Tdetf
ESCF[1:0] = 0h
180 μsec Note1)
Note1) Design reference value; no production test performed.
Tdetr
PTH
0.5*VDD
VOUT
DET1, 2
0.5*VDD
Tdetf
Vhys
Komentarze do niniejszej Instrukcji