CONFIDENTIAL [AK8999A/AW/AD]
MS1600-E-00 2014/05
- 22 -
7.2.6.2) Sensitivity Temperature Drift Adjustment Circuit
VDD = 3, 3.3, 5V ± 10%, Ta = -40 to 105ºC, register default, unless otherwise note
Parameter Symbol Conditions Min. Typ. Max.
Units
Description
Measurement in test mode after offset voltage and span voltage adjustment
1
st
order
coeff.
Adj. range
DS1+ ESTP/N[8] = 0h
ESTP/N[7:0] = 8Bh
+2500
ppm/C
DS1- ESTP/N[8] = 1h
ESTP/N[7:0] = DEh
-4000
ppm/C
Adj. step DS stp 18
ppm/
C
Note) Design reference value; no production test performed.
7.2.7) LPF, S/H & Buffer
VDD = 3, 3.3, 5V ± 10%, Ta = -40 to 105ºC, register default, unless otherwise note
Parameter Symbol Conditions Min. Typ. Max.
Units
Description
Measurement in test mode after offset voltage and span voltage adjustment
LPF cufoff
frequency
Fc1
40 60 80
kHz
S/H&Buffer gain SHG 1.935 2.222 2.523 times
S/H&Buffer out
pre-adj. error
SHerr
-65 65
mV
BUF gain adj.
width
Bufg
1.000 1.111 1.222
times
VOUT output
voltage range
Vbuf+ Load resistance
9.5k
(to VDD or VSS)
0.98
*VDD
V
Vbuf- 0.02
*VDD
V
BUF feedback
resistor value
Rbuf
102 146 190
k
7.2.8) Level shift
VDD = 3, 3.3, 5V ± 10%, Ta = -40 to 105ºC, register default, unless otherwise note
Parameter Symbol Conditions Min. Typ. Max.
Units
Description
Measurement in test mode after offset voltage and span voltage adjustment
Output reference
Voltage
adj. width
(Level shift)
Vlv+
Max
ELV[8] = 1h
ELV[7:0]
=
FFh
1.00
*VDD
V Note1)
Vlv-
Min
ELV[8] = 0h
ELV[7:0]
=
FFh
0.00
*VDD
V Note1)
Adj. step
Vlstp 0.002
*VDD
V
Note1) It is limited from 0.02*VDD to 0.98*VDD by the VOUT output range (Vbuf+, Vbuf-).